Scientific and technical journal

«Equipment and technologies for oil and gas complex»

ISSN 1999-6934

Equipment and technologies for oil and gas complex
Analysis of approaches to assessing the impact of high-voltage AC power lines on underground pipelines

UDC: 622.692.4.053:621.315.1
DOI: 10.33285/1999-6934-2022-2(128)-79-87

Authors:

RAKITO OLEG N.1

1 Ukhta State Technical University, Ukhta, Russian Federation

Keywords: alternating current, electrochemical protection, gas pipeline, oil pipeline, power transmission line, inductive influence

Annotation:

This article presents an analysis of approaches to assessing the impact of high-voltage AC power lines on underground pipelines. The article considers domestic and foreign regulatory documents on a given problem, as well as articles of domestic and foreign authors. The main criteria for assessing the danger of power lines inductive influence are determined, the values and nature of these criteria are compared. The article also proposes a classification of the factors that negatively influence of high-voltage lines on an underground pipeline.

Bibliography:

1. Myul'baer A.A. Vliyanie vozdushnykh liniy peremennogo toka na stal'nye truboprovody // Tekhnicheskie nauki – ot teorii k praktike. – 2014. – № 31. – S. 45–52.
2. Hanson H.R., Smart J. AC corrosion in a pipeline located in a HVAC utility corridor // Corrosion. – NACE, 2004. – Paper No. 4209.
3. Wakelin R.G., Gummow R.A., Segall S.M. AC corrosion. Case histories, tests procedures and mitigation // Corrosion. – NACE, 1998. – Paper No. 565.
4. Ragault I. AC corrosion induced by V.H.V. electrical lines on polyethylene coated steel gas pipelines // CORROSION 98, San Diego, CA, USA, March 22–27. – 1998. – Paper No. NACE-98557.
5. Furkin A.V., Tret'yakova M.V., Aginey R.V. Vliyanie protekayushchego po podzemnomu truboprovodu postoyannogo elektricheskogo toka na potentsial "truba–zemlya" // Izv. Komi nauch. tsentra UrO RAN. – 2014. – № 1(17). – S. 80–83.
6. Laboratory test results of AC interference on polarized steel / F. Bolzoni, S. Goidanich, L. Lazzari, M. Ormellese // Proc. of Corrosion/2003, San Diego, CA, USA, April 16–20. – Houston, TX, USA: NACE International, 2003.
7. Goidanich S., Lazzari L., Ormellese M. AC corrosion – Part 1: Effects on overpotentials of anodic and cathodic processes // Corrosion Science. – 2010. – Vol. 52, Issue 2. – P. 491–497. – DOI: 10.1016/j.corsci.2009.10.005
8. Laboratory testing on the influence of alternated current on steel corrosion / F. Bolzoni, S. Goidanich, L. Lazzari [et al.] // Proc. of Corrosion/2004, New Orleans, LA, USA, 22 March – 1 April. – Houston, TX, USA: NACE International, 2004.
9. Effects of Stray AC Interference on Corrosion Behavior of X70 Pipeline Steel in a Simulated Marine Soil Solution / Yingchao Li, Cheng Xu, Ronghua Zhang [et al.] // Int. J. of Electrochemical Science. – 2017. – Vol. 12. – P. 1829–1845. – DOI: 10.20964/2017.03.18
10. Corrosion Behavior of X70 and X80 Pipeline Steels in Simulated Soil Solution / Xinhua Wang, Xuting Song, Yingchun Chen [et al.] // Int. J. of Electrochemical Science. – 2018. – Vol. 13. – P. 6436–6450. – DOI: 10.20964/2018.07.12
11. Luyao Xu, X. Su, Y.F. Cheng. Effect of alternating current on cathodic protection on pipelines // Corrosion Science. – 2013. – Vol. 66. – P. 263–268. – DOI: 10.1016/j.corsci.2012.09.028
12. Luyao Xu, Cheng Y.F. A Real-Time AC/DC Measurement Technique for Investigation of AC Corrosion of Pipelines and Its Effect on the Cathodic Protection Effectiveness // Proc. of Corrosion 2013 Conf. & Expo., Orlando, FL, USA, March 17–21. – Houston, TX, USA: NACE International, 2013.
13. GOST 9.602-89. Edinaya sistema zashchity ot korrozii i stareniya. Sooruzheniya podzemnye. Obshchie trebovaniya k zashchite ot korrozii. – Vved. 1991–01–01. – M.: Izd-vo standartov, 1989. – 59 s.
14. Yabluchanskiy P.A. Obosnovanie meropriyatiy po zashchite podzemnykh neftegazoprovodov ot korrozionnogo vozdeystviya vysokovol'tnykh liniy elektroperedachi peremennogo toka: dis. … kand. tekhn. nauk: 25.00.19. – SPb., 2014. – 126 s.
15. Furkin A.V. Sovershenstvovanie metodik identifikatsii i otsenka opasnosti istochnikov bluzhdayushchikh tokov, vozdeystvuyushchikh na magistral'nye neftegazoprovody: dis. … kand. tekhn. nauk: 25.00.19. – Ukhta, 2012. – 154 s.
16. Furkin A.V., Tret'yakova M.V., Aginey R.V. Laboratornye issledovaniya vliyaniya protekayushchego po truboprovodu elektricheskogo toka na znacheniya potentsiala "truba–zemlya" // Truboprovodnyy transport: teoriya i praktika. – 2011. – № 3(25). – S. 41–44.