CALCULATION OF FRESH WATER DEMAND FOR GAS CONDENSATE - OIL MIXTURE WASHING AT BOOSTER COMPRESSOR STATION OF ORENBURG PGPU
UDC: 622.691.4.052:66.07
DOI: -
Authors:
Roudenko Sergey V.1,
Khoutorianski Fridel M.1,
Kapustin Vladimir M.1,
Molchanova Zinaida V.2
1 Gubkin Russian State University of oil and gas2 CEO of the JSC «Gazprom dobycha Orenburg»
Keywords: gas condensate, dehydration
Annotation:
The design technology of preparation of gas condensate and oil on gas treatment plant and booster compressor station doesnt guarantee the requirement of desalting degree. The technological scheme of fresh water flushing block of a mix of condensates and oil and its technological parameters are proved by calculations.
Bibliography:
1. Никитин В.И., Донсков К.В., Молчанова З.В., Хуторянский Ф.М. Подготовка конденсата на промысле и ЭЛОУ Оренбургского ГПЗ//Газовая промышленность. -2001. -№ 6 -С. 41-42
2. Хуторянский Ф.М., Гафаров Н.А., Молчанова З.В. и др. Модернизация технологической схемы подготовки Копанского газоконденсата//Бурение и нефть. -2002. -№ 9. -С. 34-36